Boiler Water Treatment

Boiler Water Treatment

Steam remains a critical utility across industrial facilities, powering heating processes and direct production requirements. Ensuring reliable steam generation requires a well-designed chemical treatment program, correct application, and continuous monitoring.

Challenges such as scale deposition, corrosion, sludge accumulation, carryover, and foaming can reduce efficiency, damage equipment, or even lead to catastrophic failure.

HydroGuard provides tailored solutions to safeguard boiler systems and maximize plant life and efficiency.

Product Name

Composition

Comments

Corro Guard 500

Amine based corrosion inhibitor

Condensate treatment

Scale Guard 777

Phosphate based scale Inhibitor

Phosphate based – liquid – boiler internal

Oxyguard 555

Sulphite based treatment

Oxygen scavenger sulphite based

PH Guard 48

Alkalinity improver

pH and sludge conditioner

Scale Guard 81H02

Neutralizing amines condensate treatment

Condensate corrosion inhibitor

Scale Guard 81H03

Combined condensate corrosion inhibitor with oxygen scavenger

Oxygen scavenger/passivator (HP Application)

Scale Guard 81H04

Cyclohexylamine based corrosion inhibitor

Condensate corrosion inhibitor

Scale Guard 81H05

Neutralizing amines condensate treatment

Boilers & closed recirculation system

Scale Guard 81H06

Filming amines condensate treatment

Condensate corrosion inhibitor

Scale Guard 81H07

Amine based corrosion inhibitor

Condensate corrosion inhibitor

Scale Guard 81H08

DEHA based corrosion inhibitor

Neutralizing amine and food grade oxygen scavenger

Scale Guard 81H09

Catalysed DEHA based oxygen scavenger

Oxygen scavenger for high pressure boilers

Scale Guard 81H10

Amine based corrosion inhibitor

Combined condensate corrosion inhibitor with oxygen scavenger

Scale Guard 81H11

Carbohydrazide based corrosion inhibitor

Oxygen scavenger for use in steam raising plant

Scale Guard 81H12

Phosphate based corrosion inhibitor

Corrosion inhibitor for high pressure boilers

Product Details

Product Name- HYDROGUARD

Description

Application

Corro Guard 500

Amine based corrosion inhibitor

Condensate treatment

Scale Guard 777

Phosphate based scale Inhibitor

Phosphate based – liquid – boiler internal

Oxyguard 555

Sulphite based treatment

Oxygen scavenger sulphite based

PH Guard 48

Alkalinity improver

pH and sludge conditioner

Scale Guard 81H02

Neutralizing amines condensate treatment

Condensate corrosion inhibitor

Scale Guard 81H03

Combined condensate corrosion inhibitor with oxygen scavenger

Oxygen scavenger/passivator (HP Application)

Scale Guard 81H04

Cyclohexylamine based corrosion inhibitor

Condensate corrosion inhibitor

Scale Guard 81H05

Neutralizing amines condensate treatment

Boilers & closed recirculation system

Scale Guard 81H06

Filming amines condensate treatment

Condensate corrosion inhibitor

Scale Guard 81H07

Amine based corrosion inhibitor

Condensate corrosion inhibitor

Scale Guard 81H08

DEHA based corrosion inhibitor

Neutralizing amine and food grade oxygen scavenger

Scale Guard 81H09

Catalysed DEHA based oxygen scavenger

Oxygen scavenger for high pressure boilers

Scale Guard 81H10

Amine based corrosion inhibitor

Combined condensate corrosion inhibitor with oxygen scavenger

Scale Guard 81H11

Carbohydrazide based corrosion inhibitor

Oxygen scavenger for use in steam raising plant

Scale Guard 81H12

Phosphate based corrosion inhibitor

Corrosion inhibitor for high pressure boilers

FAQs

How does corrosion impact boiler systems, and how can it be minimized?

Corrosion occurs due to oxygen, carbon dioxide, or improper pH, leading to pitting, leaks, and tube failures. HydroGuard recommends oxygen scavengers, alkalinity builders, and regular water analysis, which collectively protect metal surfaces from oxidation and maintain boiler integrity.

Why is boiler water treatment essential?

Untreated boiler water can cause scale, corrosion, and foaming, which reduce heat transfer efficiency, increase fuel costs, and may lead to boiler failure. HydroGuard provides chemical programs, monitoring tools, and maintenance guidance to ensure safe, efficient, and reliable boiler operation.

What causes scale formation in boilers, and how can it be prevented?

Scale forms when minerals like calcium and magnesium precipitate due to high boiler temperatures. HydroGuard’s phosphate-based dispersants and threshold inhibitors prevent deposit formation. Maintaining correct cycles of concentration and water softening also reduces scaling risk.

What is the role of oxygen scavengers in boiler water treatment?

Dissolved oxygen reacts with metal surfaces, accelerating corrosion. HydroGuard’s oxygen scavengers, such as sodium sulfite and hydrazine, chemically remove oxygen from water, ensuring long-term protection of boiler tubes and pressure vessels.

 

What are the benefits of HydroGuard boiler water treatment chemicals?

HydroGuard’s boiler treatment programs prevent scale, corrosion, and foaming, improving heat transfer efficiency, reducing fuel costs, minimizing downtime, and extending the operational life of boilers.

 